Physics · Chemistry · Measurement
You have probably never had it explained quite like this — have you?
But it really pays to get to the bottom of it.
Calculations, measurement curves, primary sources — and a friendly explanation of the kind you rarely get.
For decision-makers · operators · managing directors
You know the situation: a hydraulic pump fails. A cylinder no longer seals. A hose bursts — for the third time, in the same place. The foreman says: “That's normal wear.” The workshop says: “That comes with time.” And you, as the decision-maker, accept it — because rarely does anyone offer a better explanation.
The explanation exists — it is just rarely communicated. In 70–90 % of all hydraulic failures worldwide, the cause is the same: oil contamination by microparticles and water, which no standard filter removes completely. This is not a marketing promise — it is the documented state of research: Parker Hannifin, Bosch Rexroth, NFPA, ISO 4406. Up to 9 out of 10 of your failures would be physically avoidable.
Oil circulates through pumps, valve blocks, cylinders and hoses. With every pressure pulse, abrasion produces microparticles — smaller than 5 µm, completely invisible to the human eye. These particles fit exactly into the manufacturing clearances of your components: valve spools, pump vanes, cylinder liners. They grind — with every load cycle, without interruption.
Then there is water: condensate from temperature fluctuations, often only 0.1–0.2 % of the oil volume — almost imperceptible. Together with oil degradation products, water forms acid that corrodes valve spools and cylinder liners from the inside. At hose bends, flow separation causes cavitation: vapour bubbles collapse with local pressures of up to 10,000 bar. Hose inner walls are destroyed — in months, not years.
During an oil change, 85–95 % of the old oil is drained. 5–15 % remains in lines, valve blocks and cylinders — together with the entire contamination potential of all component surfaces. The fresh oil reaches the contamination level of the old oil within a few operating hours. Oil changes postpone the problem. Ultra-fine filtration tackles the cause.
What you as a decision-maker can do now
At the next failure — pump, cylinder, hose — you now have the basis to ask precise questions. Three questions every maintenance manager must be able to answer:
“What ISO 4406 particle class does our oil currently have?”
“What is the water content — and how do we measure it regularly?”
“What are we doing about the residual contamination left behind after every oil change?”
Anyone who understands the relationships can make an informed decision — because the physics is documented, the costs are calculable, and the solution is on the table.
And now you know the reason too
The physics is clear. The measurements are reproducible. The international technical literature is consistent. Ultra-fine filtration based on the FLOWLOGIC principle filters down to below 1 µm — far below the damage range and far below anything that standard filters, oil changes or maintenance intervals will ever achieve.
What you read on this page is an in-depth look at how lubricants, hydraulic oils, heat-transfer oils and insulating oils work — that is, oils and greases that lubricate, transmit power and heat, and provide electrical insulation — and at what damages them in the process. These are calculations, measurement results and citable sources. Show this page to your maintenance manager. Ask why you did not know this before.
▶ For decision-makers — an introduction without formulas
▶ The story of oil — in animated graphics
Introduction · Made visible
Four graphics. Each shows exactly one thing. Together they give the complete picture: why oil changes do not solve the problem, and what ultra-fine filtration based on the FLOWLOGIC principle does differently (schematic representation).
Particles accumulate — contamination keeps rising
It slows the rise — but does not solve the problem. The oil-change cycle starts all over again.
Continuous sub-micron filtration — the oil gets better, not worse.
Standard filter vs. ultra-fine filtration — the same period, two completely different results.
A partial flow of the engine oil passes continuously through the ultra-fine bypass filter. Particles are retained there, and the cleaned oil flows back into the oil sump. Because the oil passes through the filter many times per hour, it becomes cleaner and cleaner as operating time increases — as a guideline, a car reaches a high level of oil cleanliness after around 1,000 to 2,000 km.
Red coarse particles are retained in the filter · cleaned oil flows back into the oil sump (green dots, down to < 1 µm)
W1 · Particle contamination
Isn't it hard to imagine? Particles twenty times smaller than a human hair — invisible, inaudible — cause 90 % of engine wear. It is tolerated, more or less, because nobody explains what is really going on. Take a look at how the particle population develops — something you can only see when you treat your oil to the highest standard, not when you simply drain it.
Bearing failures, pump damage, valve wear — in 75 % of cases the cause is particle contamination in the oil. Yet the visible coarse particles are not the problem. The decisive wear particles are twenty times smaller than a human hair.
Bearings, valves and pumps have manufacturing tolerances and operating clearances of 1–5 µm. A particle that fits exactly into this clearance acts like sand in a gearbox — it cannot escape and cannot be flushed out; instead, it keeps grinding the surfaces under changing loads.
| Particle size | Visibility | Standard car filter | Wear effect |
|---|---|---|---|
| > 40 µm | with the naked eye | ✓ filtered | Coarse particles — mechanical blockage |
| 20–40 µm | barely visible | ✓ partly filtered | considerable — accelerated abrasion |
| 10–20 µm | microscope required | ✗ not filtered | critical — fits into bearing clearances |
| 2–5 µm | electron microscope | ✗ completely ineffective | 90 % of engine wear |
| < 1 µm | not visible | ✗ standard filters do not capture them | Range of ultra-fine filtration (down to < 1 µm) |
Key finding (SKF Group / NTF Filter): 75 % of all bearing failures are attributable to particle contamination. Of this, 90 % of the wear mass is caused by particles in the 2–5 µm range — precisely the range that no conventional filter reaches. Standard car filters only start at ≥ 20–40 µm. The gap between the filter limit and the centre of damage is an order of magnitude.
To help you picture it: the following graphic shows how particles move before and after the filter element. Use the slider to set the filter fineness and watch which particles remain in the oil.
● Coarse particles ● Fine particles ● Microparticles ● Sub-micron
Left: oil in service with all particle sizes | the filter element retains particles that are too large | Right: what remains in the oil after the filter
The ISO 4406:2021 standard classifies oil cleanliness by three particle sizes (>4 µm, >6 µm, >14 µm). Each class improvement halves the particle count. In a field analysis (hydraulic oil of a construction machine), the cleanliness class improved from NAS 12 to NAS 2 — i.e. by 10 classes — in only 300 operating hours and without an oil change.
How does engine-oil cleanliness develop in service? The curves schematically show the same effect for different initial qualities: the standard filter only retains coarse particles, while ultra-fine bypass filtration continuously reduces particle size down into the sub-micron range (model representation, not an individual measurement).
Fresh oil as supplied is often only lightly pre-filtered (~25 µm) · standard filter stagnates · with ultra-fine filtration, in the sub-micron range after a short operating time
Higher-quality fresh oil starts at ~12 µm · a standard filter rated ≥ 20 µm has no effect in this range · with ultra-fine filtration down into the sub-micron range
Premium fresh oil starts at ~5 µm · here too the standard filter stagnates · with ultra-fine filtration continuously below that · Individual green dots (2–5 µm): freshly generated wear particles on their way to the filter
Trucks and commercial vehicles: Truck engines work with large oil volumes (20–50 L). The volume buffers short-term contamination peaks but does not solve the underlying problem. Standard filters (25–40 µm) cannot hold a stable curve here either; depending on load, cold starts and dust ingress, oil cleanliness fluctuates considerably. Ultra-fine bypass filtration continuously reduces particle size down into the sub-micron range.
Truck fresh oil ~30–35 µm · standard truck filter only retains from ~25 µm · 2–25 µm remain in the oil · with ultra-fine filtration down into the sub-micron range
High-quality synthetic truck oil starts at ~25–28 µm · standard filter stagnates above 25 µm · with ultra-fine filtration continuously in the sub-micron range
Conclusion
Ultra-fine filtration works continuously down to < 1 µm — covering the entire critical 2–5 µm window. Particles that would otherwise grind down bearings, valves and pumps are continuously removed from the system. The oil improves with every operating hour instead of getting worse.
W2 · Additive chemistry
Agglomeration through Ostwald ripening — now that is something. Yet hardly anyone knows about it. Wouldn't it be something if everyone knew? It really is astonishing: physics proves it, chemistry shows it — and nobody seems to care. Not yet.
Engine oil does not degrade chemically by itself — it becomes unusable through dirt and the consumption of its protective additives. The most important additive is ZDDP (zinc dialkyldithiophosphate) — the primary wear protection in every engine oil. Its depletion is neither linear nor predictable.
On contact with metal surfaces under pressure and temperature, ZDDP forms a glass-like protective tribofilm — a protective layer only a few nanometres thick that prevents metal-to-metal contact. Without this layer, the metal surfaces touch directly. Every cold start, every full-load phase and every contamination with particles accelerates its depletion.
Under heat and oxygen, oil molecules react in a self-reinforcing radical chain. Metal particles in the oil act as catalysts — dirty oil oxidises measurably faster than clean oil. Antioxidants (including ZDDP) interrupt the chain — but are irreversibly consumed in the process.
Soot nanoparticles (5–50 nm) are thermodynamically unstable. They grow continuously through Ostwald ripening and coagulation — until they reach the most abrasive, critical range (1–5 µm). Early filtration down to below 1 µm interrupts this growth process before critical sizes develop.
The graphic shows the process from left to right: tiny soot particles collide in the oil, grow into larger clusters (agglomerates) and are retained by the filter from about 1 µm upwards.
Nanoparticles (dark grey) → grow into agglomerates (orange) → are separated at the filter and fade out
Cars and light vans with 3.5–9 litre oil capacity typically lose 0.3–1.5 L of oil per 20,000 km through combustion — plus the oil removed when the conventional main filter is changed (0.5–1.0 L). With ultra-fine filtration in service, the main filter is still replaced, but less often and without draining the oil. Depending on vehicle size, this results in 20–26 % fresh-oil top-up every 20,000 km — with every litre topped up, fresh ZDDP additives are introduced. After 60,000 km with ultra-fine filtration and no formal oil change, 50–60 % of the oil has, by calculation, been replaced by fresh oil — across the entire vehicle class, from small cars to light vans.
Critical point: Metal particles in the oil act as catalysts for ZDDP depletion. Dirty oil consumes its protective additives demonstrably faster than clean oil — the exact factor depends on operating conditions, but the direction is physically indisputable. This means: the dirtier the oil, the faster ZDDP depletes — a self-accelerating process.
Conclusion
Ultra-fine filtration keeps the oil continuously clean — largely eliminating catalytic ZDDP depletion by metal particles. The natural top-up effect (fresh-oil replenishment) is sufficient to keep the ZDDP level high. The result in practice: Oil-change intervals are multiplied — e.g. 100,000 km without an oil change in the 1999 field test, a car with over 540,000 km without an oil change, and a truck fleet with around 15 million km without an oil change (ALDI SÜD, reference letter 2012).
W3 · Engine oil · Short trips
Physics proves it, chemistry shows it — and nobody seems to care. But wait: this is exactly where it gets interesting. Because now you know it too.
Short-trip vehicles — vehicles rarely driven more than 10–15 km at a time — are subject to a particular damage mechanism that cannot be controlled with conventional oil-change intervals. The cause: condensation water that does not fully evaporate from the engine.
| Phase | Process | Consequence |
|---|---|---|
| Cold start | Combustion produces water vapour (H₂O) and blow-by gases (SO₂, NOₓ) | Water condenses in the cold crankcase |
| Short trip | Engine reaches max. 70–85 °C oil temperature — water only evaporates from 100 °C | Water remains in the oil and accumulates over many short trips |
| Water content >0.1 % | Water + SO₂/NOₓ (blow-by) → H₂SO₃, HNO₂ (sulphurous / nitrous acid) | TBN (total base number) is consumed — the protective mechanism is exhausted |
| TBN exhausted | Free acids attack metal parts — bearings, cylinder walls, cams | Corrosive wear — invisible, but measurable |
| Standstill corrosion | Water settles on metal surfaces — oxidation overnight / over the weekend | Rust pitting on bearing surfaces becomes abrasive after a cold start |
Castrol study (representative oil-sample analysis)
In every second oil sample analysed was found to contain foreign substances such as condensation water and fuel residues. Condensation water reduces lubricating performance and weakens corrosion protection through increasing acid formation. Especially with frequent short-trip operation, oil degradation is considerably accelerated.
Conclusion for short-trip vehicles
The filter insert absorbs water from the oil almost completely — breaking the acid-formation chain right at its source. Less water → less acid → less TBN consumption → less corrosive wear.
Recommended filter-insert change interval for cars: as a rule, every 15,000–20,000 km — this has proven itself in practice. With predominantly short-trip operation, and in regions with high humidity or large temperature fluctuations, rather every 15,000 km: here the oil is stressed particularly quickly, and the water-absorption capacity of the insert is exhausted sooner.
W4 · Hydraulics · Own calculation
Do you see how this develops? Three mechanisms. Simultaneously. At the same spot. And every time the hose bursts, people say: normal wear. Maybe. Or it is water in the oil — and nobody has explained to you what that does at a bend.
Hose failures in hydraulic systems occur disproportionately at bends — and they usually start from the inside. External influences (chafing, UV, ageing of the rubber) do not fully explain this. The following calculation shows why water in hydraulic oil has a threefold damaging effect at every bend.
| Quantity | Value | Remark |
|---|---|---|
| Inner diameter | d = 25 mm | typical hydraulic pressure hose |
| Bend angle | 60° | common installation geometry |
| Bend radius | R = 100 mm = 4 × d | Minimum per EN ISO 6945 |
| Operating pressure | P₀ = 200 bar | standard mobile hydraulics |
| Flow rate | Q = 100–150 L/min | medium-sized construction / agricultural machine |
| Oil density | ρ_oil = 870 kg/m³ | ISO VG 46 hydraulic oil at 50 °C |
| Oil viscosity | μ = 0.046 Pa·s | ISO VG 46, 50 °C operating temperature |
| Water content | 1 % (0.5–2 % typical) | measured field values, Castrol study |
The Stokes number describes whether a particle follows a curve (St ≪ 1) or shoots straight ahead (St ≫ 1).
Water (ρ = 1000 kg/m³) is heavier than oil (ρ = 870 kg/m³). At every bend, a centrifugal acceleration acts on the fluid that reliably drives water to the outer wall.
The accumulated water slug strikes the outer wall of the bend. Joukowsky's equation describes the resulting pressure surge — the standard reference in fluid mechanics for water hammer in pipelines.
At the same time, the centrifugal flow causes a pressure drop on the inner side of the bend. Vapour bubbles form and collapse abruptly in the subsequent high-pressure zone.
| Mechanism | Location at the bend | Pressure peak | Effect |
|---|---|---|---|
| Centrifugal water accumulation | Outer wall | — | Water reliably concentrates at bends |
| Joukowsky water hammer | Outer wall | +38 bar cyclic | Fatigue cracks in the inner wall |
| Cavitation erosion | Inner wall + outer wall | up to 10,000 bar (µs) | Pitting, delamination of the inner liner |
Explanation of observed damage patterns
Hose failures begin from the inside, at bends — not through external influences. All three mechanisms hit the same spot at the same time. Hose inspections under the German DGUV/BGG rules are mandatory precisely because this damage cannot be seen from the outside in advance — the inner wall fails first. Source of the physical principles: Joukowsky (1900), Rayleigh (1917), confirmed by a CFD study (ResearchGate, 2013).
The pump draws oil from the tank. A partial flow passes continuously through the ultra-fine filter and returns cleaned to the tank, independently of the main circuit. Oil cleanliness thus increases with every operating hour. In a field analysis (hydraulic oil of a construction machine), the cleanliness class improved from NAS 12 to NAS 2 within 300 operating hours, without an oil change.
Every pass through the filter returns more cleaned oil (green dots) to the tank
Hydraulic systems operate at pressures of over 400 bar. Particles in the 1–10 µm range are particularly harmful to servo valves, pumps and cylinders. Ultra-fine filtration and dewatering based on the FLOWLOGIC principle clean the oil beyond the usual cleanliness levels of new oil: in a field analysis, the cleanliness class improved from NAS 12 to NAS 2. The three curves schematically show how typical initial qualities develop (model representation, not an individual measurement).
Hydraulic systems vary widely in size: refuse collection vehicle (~180 L) · excavator / construction machine (200–500 L) · injection-moulding machine or large press (1,000–2,000+ L).
For larger systems, several filters are connected in parallel. The number required is sized individually — it does not increase linearly with the oil volume.
Example from practice: 1,000 L of oil · 4 × 20 cm filters at approx. 1–1.5 L/min each (together approx. 4–6 L/min) → the entire oil volume passes through the filters around 24 to 36 times in 100 operating hours (h). The time scale below is therefore a guideline — depending on system size, flow rate and number of filters.
Standard hydraulic oil · 8–10 µm · valve clearances (2–8 µm) are kept continuously clean
Well-maintained hydraulic oil · 5–8 µm · standard filtration stagnates above the filter limit · with ultra-fine filtration down into the sub-micron range
Premium hydraulic oil · 2–5 µm · here too standard filtration stagnates · with ultra-fine filtration down into the sub-micron range
Conclusion
Ultra-fine filtration removes water from the hydraulic oil almost completely. With almost complete dewatering (field analysis: from 5,000 to 160 ppm), all three damage mechanisms are greatly reduced at the same time: less centrifugal accumulation, fewer Joukowsky pressure surges, less cavitation erosion. The hose “sees” only homogeneous, clean oil at constant operating pressure. Longer hose service life is a direct, physically demonstrable consequence.
W5 · Tribology · Measurement
Whoa — who would have thought? Oil that gets better rather than worse? Perhaps that is why it is not widely known. Imagine if every litre of oil only had to be replaced in exceptional cases. And what could stop us now from going into even more detail?
The Reichert wear balance is a standardised test method for lubricating-film load capacity — the ability of an oil to keep two metal surfaces apart under load. In the field test with ultra-fine filtration (100,000 km without an oil change), the load-carrying capacity was 4.25 times that of fresh branded oil. Here is the physical reason.
A rotating steel element is pressed against a flat counter-surface under a defined load — with the test oil between them as the lubricant. The test measures the load at which the lubricating film fails and metal-to-metal contact occurs. The higher the load-carrying capacity, the better the oil protects under real operating conditions.
| Condition | Load-carrying capacity | Interpretation |
|---|---|---|
| Fresh oil, unfiltered | 100 % (reference) | Initial condition |
| Standard oil after 25,000 km | ~75 % | Particles damage the tribofilm |
| Standard oil after 50,000 km | ~55 % | ZDDP depleted, particles accumulated |
| Standard oil after 100,000 km | ~40–50 % | Oil-change sawtooth pattern |
| With ultra-fine filtration, 100,000 km | 425 % (4,25×) | extremely thin carbon layer, clean oil |
Values for standard oil: schematic model values for illustration. Value with ultra-fine filtration: 1999 field test (Reichert wear balance).
Measurement: 1999 field test (certified master workshops, Reichert wear balance)
Diesel car, 100,000 km without an oil change, oil continuously ultra-fine filtered, filter insert changed regularly. Result: 4.25 times higher load-carrying capacity than fresh mineral-based branded oil (wear scar area 3.41 mm² instead of 34.49 mm²), and 4 to 5 times higher than a fully synthetic branded oil as well.
Without water and wear particles in the oil, moving surfaces wear less: in pumps, control blocks, proportional and servo valves. And because no condensation water collects during standstill, corrosion is prevented.
🔍 Observation from the same field test
On visual inspection, the engine parts were coated with an extremely thin carbon layer . The testers assessed this positively: as a basis for reduced wear.
On the left, the measurement result from the 1999 field test: 100,000 km without an oil change, load-carrying capacity 4.25 times higher than with fresh branded oil. On the right, for comparison, a schematic model without ultra-fine filtration.
Left: measured (Reichert wear balance, 1999) | Right: schematic model without ultra-fine filtration
Conclusion
Wear particles and water are continuously removed from the oil, and the additives remain effective for longer. Without a change, the oil gets measurably better — not worse. Demonstrated in the 1999 field test (Reichert wear balance, 100,000 km without an oil change).
W6 · Combustion chemistry · Engine oil
But wait — this is exactly where it gets really interesting. Everyone has felt what happens in the cylinder — but hardly anyone knows what happens to the oil at the molecular level. Now you know it too. And what should stop you from diving even deeper?
Every combustion engine produces aggressive combustion residues with every power stroke. An unavoidable portion of these gases — called blow-by — passes the piston rings and enters the crankcase. There it meets the engine oil. What follows is the most frequently underestimated damage mechanism in operation.
Engine oil consists of long saturated hydrocarbon chains (C₁₄–C₃₄). At hot spots — piston skirt, turbocharger bearings, near the injectors (up to 350 °C) — these chains break homolytically. A carbon radical is formed: the starting point of a self-accelerating oxidation cascade.
At peak pressure in the cylinder (up to 180 bar, ~2,500 °C), nitrogen oxides form via the Zeldovich mechanism, SO₂ from traces of sulphur in the fuel, and nanoscale soot particles. Despite the piston rings, a portion escapes into the crankcase — this blow-by cannot be completely prevented physically. The crucial point: it is harmless as long as there is no water.
| Blow-by component | Origin | In the oil alone | + condensation water |
|---|---|---|---|
| SO₂ (sulphur dioxide) | sulphur in the fuel | dissolved, inert | H₂SO₃ → H₂SO₄ |
| NOₓ (nitrogen oxides) | Zeldovich reaction | dissolved, inert | HNO₂ + HNO₃ |
| Soot particles (10–100 nm) | incomplete combustion | Catalyst: ZDDP depletion | Abrasive + oil thickening |
| Condensation water | H₂O from combustion + cooling | remains at < 100 °C | Reaction partner: SO₂ + NOₓ → acid |
Cumulative amplification effect: Soot particles and cracking products catalyse ZDDP depletion (→ W2). More particles → faster ZDDP depletion → less protective film → more metal abrasion → even more catalytically active particles. The process is non-linear and self-reinforcing. Every operating cycle without particle removal accelerates the next damage step.
▶ The graphic in chapter W2 shows how soot particles grow together and are separated at the filter.
Conclusion
Ultra-fine filtration interrupts the cascade at both of its origins: soot particles down to below 1 µm are continuously removed from the oil — catalytic ZDDP depletion is largely suppressed. At the same time, water is almost completely absorbed: less water → less mineral acid → less TBN consumption → less corrosive wear. What inevitably forms in the cylinder is stopped in the filter — before it takes effect.
W7 · Tribology · Physical fundamentals
What could stop us now from going into even more detail? Nothing. Here is the physics behind it — and it explains why clean oil protects not just equally well, but measurably better than fresh, unfiltered oil. That sounds paradoxical. But after this chapter, you will no longer doubt it.
Why a lubricating film that is 20 % thinner can lead to ten times more wear — and why clean oil protects not just equally well, but measurably better than fresh oil. Three physical laws that have been known for a century — applied here together to ultra-fine filtration based on the FLOWLOGIC principle.
Oil is a viscous medium: it resists shear. This property — the dynamic viscosity η — determines how thick the lubricating film between two metal surfaces remains under load. Particles in the oil increase the local shear stress and effectively degrade η.
Viscosity decreases exponentially as temperature rises. Hot bearings have thinner lubricating films — while particle-induced stress peaks increase at the same time. The two effects reinforce each other: more heat and more particles mean disproportionately more wear.
The Stribeck curve (1902) shows how the coefficient of friction µ falls as film thickness increases. The decisive parameter is Λ (lambda) — the ratio of the minimum lubricating-film thickness h_min to the combined surface roughness Ra. If Λ falls below 1, the metal surfaces touch directly: wear begins.
| Regime | Λ = h_min / Ra | Coefficient of friction µ | Wear |
|---|---|---|---|
| Boundary lubrication | Λ < 1 | µ = 0,08–0,15 | Direct metal contact — maximum wear |
| Mixed lubrication | Λ = 1–3 | µ = 0,02–0,08 | Partial contact — critical transition zone |
| Hydrodynamic (EHL) | Λ > 3 | µ = 0,001–0,01 | Complete separation — no metal contact |
Archard's wear law (1953) quantifies abrasive wear precisely. The wear coefficient k is the decisive quantity — it rises drastically as soon as foreign particles in the oil initiate three-body abrasion.
Link to the Reichert measurement (W5)
The factor of 4,25× from the field test (Reichert wear balance) is consistent with Archard's law: ultra-fine filtration keeps k low by continuously removing three-body wear particles and keeps η₀ at its target level through cleanliness. The Stribeck curve remains in the hydrodynamic regime — no metal touches metal, no Archard wear sets in.
Conclusion
Clean oil is physically superior — not just cleaner. Ultra-fine filtration keeps η₀ stable (hardly any particle influence on viscosity), secures h_min (the lubricating film remains thick enough for Λ > 3) and significantly reduces three-body abrasion (k remains low according to Archard). The result: the oil gets better over time — not worse. Fresh, unfiltered oil is already contaminated after a few operating hours and is worse than continuously filtered used oil.
And it is tolerated — more or less — because nobody is informed about it. Destroying a valuable material that still has 80 % of its capacity, completely pointlessly. Surely that is not what you want, is it?
W8 · Insulating oils · Operational safety · IEC 60422
Here is a market that needs no persuading — because the standard has already done the work. Anyone who operates a transformer must maintain the oil quality. Anyone who uses ultra-fine filtration based on the FLOWLOGIC principle works continuously towards the standard — without manual intervention, without production downtime, without a six-figure repair bill.
Insulating oils in transformers and switchgear perform a dual function: electrical insulation and heat dissipation. Water is the most critical contaminant here — just a few ppm reduce the breakdown voltage dramatically. IEC 60422 and DIN VDE 0370 specify limit values that are hard to maintain consistently with conventional maintenance. With ultra-fine filtration: automatically and continuously.
The breakdown voltage — the oil's ability to insulate against electric current — decreases non-linearly as the water content rises. The relationship is physically unambiguous and governed by standards. A transformer that falls outside the standard is a source of danger.
| Water content (ppm) | Breakdown voltage | Condition | Action |
|---|---|---|---|
| < 10 ppm | > 70 kV | New oil / ideal | Target of continuous filtration |
| 10–30 ppm | 50–70 kV | Standard met | Monitoring |
| 30–60 ppm | 35–50 kV | Borderline | Initiate drying |
| > 60 ppm | < 35 kV | Critical | Immediate action — risk of breakdown |
Operators of transformers and switchgear are required by the standards to monitor their oil. The limit values leave no room for interpretation — anyone who fails to comply risks shutdown, loss of insurance cover and liability. Ultra-fine filtration and dewatering work continuously towards the limit values; the prescribed oil monitoring remains in place.
| Parameter | New oil (target value) | Operation OK | Limit value / action |
|---|---|---|---|
| Breakdown voltage (kV) | > 70 | > 50 | < 30 → immediate action |
| Water content (ppm) | < 10 | < 30 | > 50 → drying |
| Acid number TAN (mg KOH/g) | < 0,01 | < 0,1 | > 0.3 → check for replacement |
| Dissipation factor tan δ (90 °C) | < 0,001 | < 0,01 | > 0.05 → critical |
| Particles ISO 4406 | < 15/13/10 | < 17/15/12 | > 19/17/14 → filter |
The cost argument — in concrete terms
A 10,000-litre transformer without continuous care requires regular manual oil treatment: typically €8,000–15,000 per cycle (special equipment, downtime, logistics). With ultra-fine filtration, this cycle is needed much less often. An unplanned failure due to breakdown costs: six-figure consequential damage costs (production stoppage, short circuit, fire hazard, insurance claim).
Here, ultra-fine filtration is not just a cost saver — it is risk prevention.
Conclusion
Target: water content well below the IEC limit of 30 ppm (design value < 10 ppm). Tested by TÜV Bayern Sachsen (1993), including for transformer oil. Particles down to below 1 µm are continuously removed: this supports compliance with the ISO 4406 class. The rise in TAN is slowed by dewatering: H₂SO₄ and HNO₃ formation is significantly reduced. The result: compliance with standards without manual intervention. Operational safety as a permanent state — not as a reaction to a measured value.
And anyone who operates a transformer usually also operates vehicles, presses or hydraulic systems. The same solution. The same logic. Even greater savings.
Insulating oil is a subject in its own right — with its own standards, its own target groups and its own decision-making processes. Utilities, railways, industrial plants and wind farms speak a different language from fleet managers.
→ To the insulating-oil industry solution — full presentation for energy & industry
Primary literature · Standards · Studies
All calculations and statements on this page are based on peer-reviewed studies, industrial measurement series, recognised standards or standard mathematical and physical models.
Peer-reviewed · 2025
ZDDP Depletion in Urban Bus Engines
Non-linear ZDDP depletion in urban engines. Cold starts as the primary depletion factor. Basis for W2.
→ Nature Scientific ReportsIndustry study · SAE
Particle contamination and engine wear
Relationship between particle size and wear rate in engines. Basis for W1.
→ SAE InternationalStandard · 2021
ISO 4406:2021 — Hydraulic fluid power
Classification of oil cleanliness by particle concentration (4/6/14 µm). Basis for W1.
→ ISO.orgField test · Reichert wear balance
Field test of an ultra-fine oil filter, 100,000 km without an oil change
4.25 times higher load-carrying capacity of the ultra-fine filtered oil compared with fresh branded oil. Basis for W5.
Bearing research · SKF Group
75 % of bearing failures caused by particle contamination
Analysis of bearing failures worldwide. Basis for W1.
→ SKF.comPeer-reviewed · 2015
The Antiwear Action of ZDDP
Tribofilm formation by ZDDP, mechanism of additive depletion. Basis for W2.
Industry · Castrol
Risks of short trips — oil-sample analysis
Every second oil sample contains condensation water. Acid formation and corrosion in short-trip operation. Basis for W3.
→ krafthand.deCFD study · ResearchGate 2013
LDI Erosion in the Inner Wall of a Bent Pipe
Liquid droplet impingement erosion at bends. Erosion rate increases exponentially with impact velocity (exponent up to 10). Basis for W4.
→ ResearchGateFundamental physics
Joukowsky equation / hydraulic pressure surge
ΔP = ρ·c·Δv — pressure surge caused by a sudden change in flow in closed pipelines. Basis for W4.
→ Wikipedia: Water HammerCavitation
Water Droplet Erosion — Mechanisms
Rayleigh collapse model. Cavitation pressure peaks during bubble collapse. Basis for W4.
→ Wikipedia: WDEHydraulics · Acids in oil
Acids in oil — acid number and its effects
TBN consumption, acid formation in oil, corrosion protection. Basis for W3.
→ CJC.deHydraulics · Cavitation
Cavitation in hydraulic systems: destruction from the inside
Practical description of cavitation damage in hydraulic components. Basis for W4.
→ bf-hydraulik.comCombustion chemistry · 1946
The Oxidation of Nitrogen in Combustion
Zeldovich mechanism: N₂ + O• → NO + N•. NOₓ formation from 1600 °C. Blow-by acid pathway SO₂/NOₓ + H₂O → H₂SO₄/HNO₃. Basis for W6.
Fundamental physics · 1953
Contact and Rubbing of Flat Surfaces
Archard's wear law W = k·F·s/H. Wear coefficient k: 10⁻⁴ (clean) vs. 10⁻² (particles). Quantitative basis for W7.
→ DOI: 10.1063/1.1721448Standard · IEC 60422 / DIN VDE 0370
Maintenance and Supervision Guide for Insulating Oil in Electrical Equipment
Limit values for water content, breakdown voltage, TAN and particle content in transformer and switchgear oils. Basis for W8.
→ IEC.chTribology · Stribeck 1902
Die wesentlichen Eigenschaften der Gleit- und Rollenlager (The essential properties of plain and rolling bearings)
Stribeck curve: transition between boundary, mixed and hydrodynamic regimes. h_min ∝ (η₀·U)^0.7. Λ = h_min/Ra as the evaluation parameter. Basis for W7.
W9 · Life-cycle assessment · BVA / IFEU 2005
Most companies feel good when they recycle their waste oil properly. That is right. But it remains a consolation — because the damage has been done. The oil is gone. The FLOWLOGIC principle asks a different question: what if the oil did not have to be disposed of in the first place?
In 2005, the German Waste Oil Association (Bundesverband Altöl e.V., BVA) and the IFEU Institute examined the life-cycle assessment of waste-oil recycling compared with primary oil production. The result is impressive — and at the same time shows where the real solution lies.
Study result — IFEU 2005 / German Waste Oil Association (BVA)
Re-refining into base oil: environmental benefits
How much more does new production (primary production) of base oil burden the environment compared with re-refining waste oil? The burden from recycling is set to 1 in each case.
Reading example: in terms of resource consumption, primary production burdens the environment about 34 times as much as recycling.
Own illustration based on: IFEU Institute Heidelberg, life-cycle assessment 2005 commissioned by the German Waste Oil Association (BVA); cf. Ökopol expert report, Hamburg 2003/2005
Re-refining waste oil into base oil is superior to primary production in all categories.
What this means
Recycling is the right way — no doubt about it. But it presupposes that the oil has already been used up and must be disposed of. The FLOWLOGIC principle starts one step earlier: The oil stays in the machine's circuit for longer. It is changed less often. Disposed of less often. Recycled less often.
Less waste oil is not a smaller contribution to recycling — it is better environmental protection. Every oil change that does not take place avoids transport, disposal energy, refinery processes and CO₂ emissions — completely.
“Active environmental protection is a duty, earns real money and is the best marketing there is — free of charge.”
Life-cycle assessment in figures
One truck oil change: ~35 litres of engine oil + ~10 litres of hydraulic oil = ~45 litres of waste oil per event.
With ultra-fine filtration, oil-change intervals are multiplied (examples from practice: truck fleet around 15 million km without an oil change, car over 540,000 km) → correspondingly less waste oil over the vehicle's service life.
Example calculation: 100 trucks, 3 oil changes per year, 10 years: over 100,000 litres of oil remain in circulation — not as waste oil, but as a working operating fluid.
You have read the science. What would you like to do next?